Specification notes
| Product type | Low-voltage heating cable |
|---|---|
| Selection basis | Application, supply, required heat input, heated length and environmental conditions |
| Temperature definition | Maintain, continuous exposure and intermittent exposure with energized state and duration |
| Circuit definition | Startup/load current, circuit length, protection, control and terminations |
| Order configuration | Values and tolerances stated in the offered model-specific specification |
Application and purchasing decision
Low-voltage heating cable for equipment integration and pipe protection. Match the available supply, startup current, heated length and control arrangement before specifying the circuit.
Select the configuration
Compare required heat input, available supply, heated route and insulation. For a self-regulating circuit, review cold-start current and protection. For parallel constant-wattage cable, check permitted cutting zones. For series cable, define resistance, length and voltage together; do not transfer cutting rules between these technologies.
Installation and control
Route pipe-heating cable directly against the pipe outer wall beneath the insulation. Use the lower pipe positions, compatible fixing and approved terminations. Confirm grounding, circuit protection, sensor location and control requirements in the selected configuration’s instructions.
Operating conditions and boundaries
Do not select by watts per metre or a maximum temperature alone. Specify reference temperature for output, exposure duration and energized state, jacket/environment compatibility and circuit conditions. Low-voltage, high-temperature and hot-water configurations each require the applicable electrical and thermal review.
Technical documents and supply evidence
Request the offered configuration’s data sheet, assembly/dimension drawing, wiring and installation instructions and applicable test documentation. Verify document revision, manufacturer/holder, model and destination-market scope. This product page does not establish a certification or project-performance claim.
Prepare a useful quotation request
Send the complete model if known, application, pipe/equipment dimensions, fluid and target temperatures, minimum ambient, maximum exposure and duration, insulation, supply, heated length, lead lengths, control preference, quantity and destination. Attach drawings and mark unknown conditions for engineering review.
| Source model | Supply V | 16 A length m | 25 A length m |
|---|---|---|---|
| LBR-15 | 12 | 8 | 10 |
| LBR-15 | 24 | 15 | 25 |
| LBR-15 | 36 | 25 | 35 |
| LBR-15 | 60 | 35 | 40 |
| LBR-25 | 12 | 6 | 8 |
| LBR-25 | 24 | 10 | 20 |
| LBR-25 | 36 | 16 | 25 |
| LBR-25 | 60 | 25 | 35 |
Which conditions define the output rating?
Use the stated reference temperature and supply with the exact output variant. The plotted output changes with pipe temperature; maintain/exposure ratings have a different purpose.
How do I read the maximum circuit table?
Match the source model, supply, startup temperature and breaker-current column. The table is not permission to ignore breaker characteristics, voltage drop, protection, cable configuration or local installation requirements.
What should I send if I cannot choose a variant?
Send pipe/equipment dimensions, medium, minimum ambient, maintain and maximum exposure conditions, insulation, supply, length, area classification and required files. Mark unknown values for review.
What do I need to confirm before choosing this product?
Pipe/equipment dimensions and material; fluid; maintain and exposure temperatures with energized state; minimum ambient; insulation; supply; length; environment; protection and control.
Product photographs and details
Request specifications
Other series or models to review
These are navigation alternatives, not verified substitutes.
LONRIHEAT LH-GBR High-temperature self-regulating heating cableLH-GBR high-temperature self-regulating heating cable for pipe and equipment duties. Compare maintain temperature, exposure duration, startup conditions and circuit protection together.
LONRIHEAT Hot-water maintenance heating cableHeating cable for hot-water distribution temperature maintenance. Define the pipe network, target water temperature, insulation and control arrangement before selecting a configuration.Related answers, products & documents
Source and review status
CAT-2023-20P · PDF page 7 · Local supplied-catalogue reference. Company information, certification logos and project claims excluded.
- revision
- CONFIGURABLE-20261119-V1
- updated
- 2026-11-19
Prepare your configuration enquiry
Product family: Heat Tracing Cables.
Download the configuration enquiry worksheet (CSV) · Request the applicable model datasheet and quotation
Industrial Pipe Freeze Protection
Heat-loss design inputs
What Information Should Buyers Provide for an Accurate Heat-Tracing Quotation?
Model compliance and market documents