Specification notes
| Product type | Mineral-insulated resistance heating cable |
|---|---|
| Model | LH-MIC-824D |
| Conductor arrangement | Dual-core |
| Assembly definition | Heated length, cold leads, joints, terminations and supply specified together |
| Output basis | Circuit voltage and resistance at operating temperature; no universal fixed W/m |
| Material selection | Confirm sheath grade, conductor and insulation in the offered assembly specification |
| Catalogue nominal resistance (reference only) | 7.6772 Ω/m |
| Resistance data condition | Source catalogue reference temperature is unspecified. Confirm resistance and tolerance for the offered assembly; not a guaranteed operating resistance. |
Application and purchasing decision
LH-MIC-824D is a dual-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
Select the configuration
Compare the conductor arrangement and nominal resistance, then define heated length, applied voltage, cold-lead length and termination layout. Different resistance rows are not interchangeable. Confirm the sheath material against the chemical environment and actual surface-temperature limits.
Installation and control
For pipe tracing, install the heater against the pipe outer wall beneath insulation. A single longitudinal run belongs at the bottom; two runs belong on the lower sides. Follow the approved assembly drawing for bends, joints, fixing, grounding, sensing and electrical protection. Do not cut or reterminate an engineered assembly without design review.
Operating conditions and boundaries
Cable, joints, cold ends and terminations can have different limits. Confirm maintain temperature, continuous and intermittent exposure, energized state, duration, mechanical environment and area classification for the complete assembly. A catalogue temperature column is not a complete system rating.
Technical documents and supply evidence
Request the offered configuration’s data sheet, assembly/dimension drawing, wiring and installation instructions and applicable test documentation. Verify document revision, manufacturer/holder, model and destination-market scope. This product page does not establish a certification or project-performance claim.
Prepare a useful quotation request
Send the complete model if known, application, pipe/equipment dimensions, fluid and target temperatures, minimum ambient, maximum exposure and duration, insulation, supply, heated length, lead lengths, control preference, quantity and destination. Attach drawings and mark unknown conditions for engineering review.
Can I select this product from nominal W/m alone?
No. Retain voltage, reference temperature, startup, circuit length and installation conditions, and check the actual duty and limits.
Do the source logos prove approval for this order?
No. Match the certificate holder, factory, exact model/configuration, market and valid scope before making a compliance claim.
What do I need to confirm before choosing this product?
Equipment duty; heated length; resistance and its reference temperature; supply; calculated output; maintain/exposure and energized state; sheath/corrosion; cold leads; hot/cold joints and termination.
Product photographs and details
Request specifications
Other series or models to review
These are navigation alternatives, not verified substitutes.
LONRIHEAT LH-MIC-145B Mineral-insulated heating cableLH-MIC-145B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
LONRIHEAT LH-MIC-189B Mineral-insulated heating cableLH-MIC-189B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
LONRIHEAT LH-MIC-216B Mineral-insulated heating cableLH-MIC-216B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
LONRIHEAT LH-MIC-239B Mineral-insulated heating cableLH-MIC-239B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
LONRIHEAT LH-MIC-250B Mineral-insulated heating cableLH-MIC-250B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.
LONRIHEAT LH-MIC-279B Mineral-insulated heating cableLH-MIC-279B is a single-core MI heating-cable configuration. Compare nominal resistance, heated length, supply and terminations together before requesting an engineered quotation.Compare all entries in this series
Related answers, products & documents
Source and review status
CAT-2023-20P · PDF page 12 · Local supplied-catalogue reference. Company information, certification logos and project claims excluded.
- revision
- CONFIGURABLE-20261119-V1
- updated
- 2026-11-19
Prepare your configuration enquiry
Product family: Heat Tracing Cables.
Download the configuration enquiry worksheet (CSV) · Request the applicable model datasheet and quotation


Industrial Pipe Freeze Protection
Heat-loss design inputs
What Information Should Buyers Provide for an Accurate Heat-Tracing Quotation?
Model compliance and market documents